Heat Exchanger

Offering you a complete choice of products which include redundant frame joint apparatus, plate type heat exchanger, shell and tube heat exchanger, finned tube heat exchanger and parallel counter flow heat exchanger.
Request CallBack
REDUNDANT FRAME JOINT APPARATUS
Get Best Quote

REDUNDANT FRAME JOINT APPARATUS

Approx. Price: Rs 1.49 Lakh / UnitGet Latest Price
Product Brochure
Product Details:
Minimum Order Quantity1 Unit
Country of OriginMade in India

REDUNDANT FRAME JOINT APPARATUS

Technical Detail

Apparatus consists of three suspension members (spring balances) of different stiffness which are jointed at a point to form the redundant joint.

The upper end of the suspension members being tied in a position to a vertical wooden board. Arrangement is provided to apply a vertical load at the joint and to measure its horizontal and vertical displacement on a paper and also elongations and forces in the suspension members by the help of dial gauges.

Two dial gauges with 25mm travel (with magnetic bases)

Apparatus complete with a supporting stand and a set of weights.

Apparatus with data logging facility

Yes! I am Interested
Request CallBack
Plate Type Heat Exchanger
Ask For Price

Plate Type Heat Exchanger

Product Price : Get Latest Price
Product Brochure
Product Details:
Plate Heat Exchanger TypeWelded Plate and Frame
Floor Area1.75m X 1m
Plates MaterialStainless Steel
Hot Water CirculationMagnetic Pump
HeatersNi chrome Wire Heater
Digital Temp. Controller0-199.9 Degree C (For Hot Water Tank)

Plate type heat exchanger consists off ramien which independent metal plates are clamped between ahead and follower. The plates are sealed at their outer edges and around the ports by gaskets, which are so arranged that the liquid and the heating /cooling media are directed alternately into passages formed between the plates.

The hot fluid enters at the top on the right side of the fixed end cover and flows downwards through alternate channels between the plates. The Hot fluid leaves the exchanger through a connection at the bottom of the fixed end cover. The cold fluid enters at the bottom of the left side of the fixed end cover. The cold fluid flows in counter current flow through alternate channels between the plates and leaves the exchanger at the top on the left side of the fixed end cover.


Yes! I am Interested
Request CallBack
Shell and Tube Heat Exchanger
Ask For Price

Shell and Tube Heat Exchanger

Product Price : Get Latest Price
Product Brochure
Product Details:
Diameter220 Mm
Water Supply20 Lit/min
Electricity Supply1 Phase, 220 V Ac, 4 Kw
Floor Area1.5 M X 0.75 M
Shell MaterialStainless Steel
TubeOd 16mm
Shell and Tube Heat Exchanger are popular in process industries because they occupy less space and offer reasonable temperature drop. The apparatus consists of fabricated shell, inside which tubes with baffles on outer side are fitted. The present set up is a 1-2 heat exchangers, with cold water flows through shell. Valves are provided to control the flow rates of hot and cold water. Flow rates of hot and cold water are measured using Rotameters. A magnetic drive pump is used to circulate the hot water from a re-cycled type water tank, which is fitted with heaters and Digital Temperature Controller.

Yes! I am Interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
Finned Tube Heat Exchanger
Ask For Price

Finned Tube Heat Exchanger

Product Price : Get Latest Price
Product Brochure
Product Details:
Longitudinal FinsWidth 20 mm
Inner Tube Diameter32 Mm
Length500 mm
Longitudinal Fins Length500 mm
Working Temperature85 Degreec
Heat exchangers are widely used in various industries. Finned tube Heat Exchanger is a Tube-in-tube type heat exchanger. The inner tube is of Stainless steel with fins on its outside surface. Hot water flows through inner tube and cold fluid flows through the outer tube. The flow rate of hot & cold fluid is measured with the help of rotameters. Inlet and outlet temperatures of fluids are measured with the help of digital temperature indicators. A magnetic drive pump is used to circulate the hot water from a recycled type water tank, which is fitted with heaters and Digital Temperature Controller.

Yes! I am Interested
Request CallBack
Parallel Counter Flow Heat Exchanger
Ask For Price

Parallel Counter Flow Heat Exchanger

Product Price : Get Latest Price
Product Brochure
Product Details:
Water Supply10 Lit/min
Electricity Supply1 Phase, 220 V Ac, 3 Kw
Floor Area2 M X 0.6m
Heat Exchanger Length1.6 m
Hot Water CirculationMagnetic Pump
Heat exchanger is a device in which heat is transferred from one fluid to another. The apparatus consists of a concentric tube heat exchanger. Hot water flows through inner tube in one direction only and cold water flows through the outer tubes. Direction of cold fluid flow can be changed from parallel or counter to hot water so that unit can be operated as parallel or counter flow heat exchanger. Flow rates of hot and cold water are measured using Rota meters. A magnetic drive pump is used to circulate the hot water from a recycled type water tank, which is fitted with heaters and Digital Temperature Controller. 